Accurate Temperature Measurements
Accredited calibration of temperature meters, performed both in our laboratory and on-site at your premises.
Our accredited laboratory provides calibration of a wide range of temperature measuring instruments, temperature transducers. Calibrations are performed using reference standards and measurement systems with demonstrated metrological traceability. For each calibrated item, we issue a calibration certificate in accordance with ISO/IEC 17025. Results are accurate, reproducible, and internationally recognized under ISO/IEC 17025. Calibrations are carried out in our laboratory or within the accredited scope on site at the customer’s premises.
We calibrate the following instruments
Accredited:
- Glass thermometers
- Resistance thermometers
- Temperature transducers
- Thermometer chains with analog or digital indicators
- Infrared thermometers from -10 °C to 300 °C
Special Capability:
- Accredited to perform temperature calibrations on-site at customer facilities
Brands & Devices we calibrate most often
JSP
Temperature sensors (RTD/thermocouple), humidity sensors & transmitters; temperature/controllers for measurement & regulation
Sensit
Combined temperature–humidity sensors/transmitters (e.g., STH/PTSV series); RTD temperature probes
Gefran
Industrial temperature sensors (thermocouples, resistance thermometers) and related transmitters
JUMO
Temperature probes (RTD, thermocouples) and temperature transmitters; humidity portfolio available in process range
Premex
Temperature/humidity metering & logging
Comet
Thermo-hygrometers and T/RH data loggers (USB/Ethernet/IoT), incl. indoor, process, and compressed-air models
Amprobe
Handheld temperature & humidity meters and data loggers for HVAC/IAQ (e.g., TH-3 series)
Testo
Hygrometers/thermo-hygrometers and temperature/humidity data loggers across HVAC/food/pharma applications (e.g., testo 623)
Kimo (Sauermann)
Handheld thermo-hygrometers and fixed humidity transmitters for building/HVAC
UNI-T
Compact handheld temperature-humidity meters (e.g., UT333/UT333BT)
Dostmann
Temperature & humidity data loggers and digital thermometers/hygrometers (e.g., LOG series / LOG110)
Note:
The scope of accreditation, together with the associated uncertainties, is provided in the appendix. Upon agreement and within our technical capabilities, we can calibrate beyond the accredited scope as non-accredited measurements. In such cases, we provide proof of traceability to internationally recognized SI units.
Jaroslav Vrábel
Eva Chnapková
Frequently Asked Questions
Can calibrations be performed at my premises?
Yes, we are accredited to carry out temperature (-20 to 250) °C calibrations on-site at customer facilities.
What is your accredited range for infrared thermometers?
We calibrate infrared thermometers from -10 °C to 300 °C.
Which humidity measurement devices can you calibrate?
We calibrate capacitive and hair hygrometers, transducers, hygrographs, and combined temperature-humidity recorders.
How often should temperature and humidity instruments be calibrated?
Annual calibration is common, but critical applications or regulatory requirements may require more frequent checks.